Api 16d Blowout Preventer Hose

Api 16d Blowout Preventer Hose

Our high-performance BOP hoses are designed for hydraulic use and certified to withstand fire, high heat and pressures in safety critical applications. All Fire Armor BOP hose assemblies are tested and approved by Lloyd’s Register, complying with American Petroleum Industry API 16D guidelines to meet and exceed OD/1000/499 flame testing at 700 °C for five minutes.Working pressure up to 5000 PSI,dimension up to 2”.

Description

  • Applications

    Hydraulic control pipeline for BOP control equipment.A structure of lining , reinforcement , Flame retardant insulation and protection cover , with coupling patent design (No.ZL 00214874 9)Standard: API Spec 16D、Q/0681、SLT001

  • Cover

    Red Flame Retardent CR Rubber Over Layers Of Heat Resistant Fibre

  • Reinforcement

    Two Wire Braid or 4 or 6 Wire Spirals

  • Tube

    NBR

  • Working Pressure

    14-45MPa

  • Temperature range

    -20℃(44°F)~+121℃(250°F)under temperature 1093℃(2000°F), the hose perform well with working pressure in 5 minutes